EMI/EMC Test and Measurement
EMC Design Consultancy Group
EMI Filter
Shielding
Grounding
Bonding
Lightning

Features
E-field Shielding better than 100 dB from 30 MHz.
Applications
Radiated emission and susceptibility of electrical or electronics product can be measured upto 6 GHz.
Users
Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Service name
Measurement of Radiated emission from electrical or electronic product as per CISPR 32,Ed.2 : 2015 FCC part 15 standard
Features
Measurement distance can be set 3M and Rx antenna height can be varied from 1M to 4M. 360º azimuth rotation of the EUT can be given
Applications
Electrical or electronics product with input current less than 20A.
Users
Industries in and around Kolkata and Eastern India
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
Facility is FCC listed. Radiated emission can be measured from 30MHz to 6 GHz.

Service name
Radiated susceptibility test of electrical or electronic product as per IEC 61000-4-3,Ed.3.2:2010 standard.
Features
Measurement distance can be set 3M and Field upto 10 V/M can be created on the EUT. Field uniformity better than 6dB for 75% or more test points.
Applications
Measurement distance can be set 3M and Field upto 10 V/M can be created on the EUT. Field uniformity better than 6dB for 75% or more test points.
Users
Railway vendors and other Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
Radiated susceptibility can be tested from 80MHz to 6 GHz and sine wave modulation at 1KHz with 80% modulation depth.

Service name
Magnetic field Immunity test of electrical or electronic product as per IEC 61000-4-8 standard.
Features
Field Immunity can be tested at 50Hz. Severity level can be upto 300 A/m for continuous and upto 1000 A/m for short duration.
Applications
Electronics product with CRT display with input current less than 20A.
Users
Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
Immunity can be tested at power line frequency and field strength upto 5 Gauss

Service name
Measurement of conducted emission from electrical or electronic product as per CISPR 11,22 FCC part 15 standard.
Features
Conducted emission measurement of 3 phase EUT is possible and input current upto 25A.
Applications
Electrical or electronics product.
Users
Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
Conducted Emission can be measured from 150KHz to 30MHz and also as per FCC standard.

Service name
ESD test of electrical or electronic product as per IEC 61000-4-2 standard.
Features
The severity level for air discharge is upto ±15 KV and contact discharge is upto ±8 KV. Pulse rise time is between 0.7nS to 1nS.
Applications
Electronic equipment sensitive to static discharge.
Users
Railway vendors and other Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
ESD test of EUT can be carried out upto ±15 KV.

Service name
EFT/Burst test of electrical or electronic product as per IEC 61000-4-4 standard.
Features
Pulse Rise time is 5 nS, Pulse width is 50 nS, Burst duration is 15 microsecond, Burst Period is 300 microsecond and Test voltage upto ± 4 KV
Applications
Electrical or electronic equipment with input current less than 16A.
Users
Railway vendors and other Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
EFT/Burst of EUT can be carried out upto ±4 KV and upto 5 KHz repetition rate.

Service name
High energy surge immunity test of electrical or electronic product as per IEC 61000-4-5 standard.
Features
Pulse Rise time is 1.2 microsecond, Pulse width is 50 microsecond and Test voltage upto ± 4 KV.
Applications
Electrical or electronic equipment with input current less than 16A.
Users
Railway vendors and other Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
Surge generator can deliver 1.2/50 microsecond voltage surge across high load resistance and 8/20 microsecond current surge into a short circuit.

Service name
Measurement of Harmonic current emission from electrical or electronic product as per IEC 61000-3-2 standard.
Features
5KVA programmable source and automated measurement.
Applications
Electrical or electronic equipment with input current less than 16A.
Users
Industries in and around Kolkata and Eastern India.
Location of facility
SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
Other Detail
Harmonic current emission from EUT can be carried out upto 16A input current.